As the power of AI exponentially scales, data centers go up across the country to house the infrastructure needed for this technology. States have taken notice, and a growing number are attaching strings to that growth: incentives to attract developers, labor standards to protect the workforce doing the building, or both. In a handful of states, those labor standards now include prevailing wage, and in some cases, apprenticeship requirements.
If your firm works in data center construction, or is considering it, here’s what’s already law, where the trend is heading, and how to think about compliance in a sector that didn’t traditionally think of itself as “public works.”
Data centers are not new, but the scale of what’s being built is. A single large-scale AI training facility can draw as much electricity as a mid-sized city, and utilities, grid operators, and state legislatures are all racing to catch up. That’s created two distinct regulation types in state legislatures:
Some legislation does both at once: offering a tax benefit or rate structure in exchange for labor commitments on the construction side. That pairing is exactly what’s driving the prevailing wage trend below.
If you’ve tracked prevailing wage and apprenticeship requirements under the Inflation Reduction Act, this will feel familiar. Data centers are following a similar policy pattern: a significant incentive or regulatory benefit, paired with labor standards.
Signed September 21, 2026, SB 886 directs the CPUC to set interconnection rules and tariffs for data centers by January 1, 2028. A data center that enters a new transmission-level interconnection agreement on or after January 1, 2027 must certify to the CPUC that its facility will meet the prevailing wage and skilled and trained workforce requirements the Energy Commission already applies to nonfossil powerplants (Public Resources Code §§25545.3.3 and 25545.3.5). In practice, this means:
To stay compliant, firms should confirm early whether the project’s interconnection agreement falls under the law, write the wage and skilled and trained workforce requirements into every contract, prime through lower-tier subcontractors, and set up certified payroll and record retention before work begins. See the bill’s language for a full description of all requirements.
Signed January 20, 2026 and effective April 1, 2026, the law requires prevailing wage payments for data center construction projects designed for annual electrical usage of five megawatts or greater after construction. It applies only to projects that commence on or after the effective date. Requirements include, but are not limited to:
Projects designed for 25 megawatts or greater may also include a project labor agreement. Contractors are jointly and severally liable for any wages, benefits, or other amounts owed to any worker not appropriately paid by a subcontractor. With liability climbing up the ladder, it’s vital that all contracting parties on a data center project verify prevailing wage applicability and set forth a compliance plan. See the bill’s language for a full description of all requirements, wage and non-wage related.
Minnesota’s approach pairs a tax incentive with a labor standard. Under SSHF16, “qualified large-scale data centers” were added to the state’s sales tax exemption for purchases of enterprise information technology equipment and computer software, effective for purchases made after June 30, 2025. A facility qualifies if it totals at least 25,000 square feet and its construction or refurbishment, equipment, and software costs reach at least $250 million within a 60-month period beginning after June 30, 2025.
In exchange, laborers and mechanics performing work to construct or refurbish these facilities must be paid the prevailing wage rate for their work. The entity seeking the exemption must certify to the state that it complied for all covered work after June 30, 2025. “Refurbish” does not include maintenance or equipment refreshment or replacement, and the work is subject to the state’s existing prevailing wage enforcement provisions. See our Minnesota prevailing wage compliance page for the state’s existing framework administered by the Department of Labor and Industry (DLI).
A few patterns are worth flagging as this trend develops:
Data centers are quickly becoming one of the most active construction sectors in the country, and state legislatures are increasingly treating them the way they’ve long treated other large public-facing infrastructure: with labor standards attached. Whether your state has already passed a prevailing wage requirement for data centers, or has a bill working its way through committee right now, the smart move is to build compliance into your planning early, not after the fact.
Have a data center project in the pipeline and want to know whether prevailing wage or apprenticeship requirements apply? Connect with our team to review your project’s state-specific obligations and make sure your compliance strategy is airtight before you break ground.